Fixed carbide-tipped cutters
Bolt-on cutters remain fixed during cutting and can be replaced individually.

A hydraulic drum attachment for reducing brush, woody debris and fallen vegetation into smaller material. Fixed cutters work around a horizontal rotor; model selection depends on the excavator and its continuous hydraulic supply.
A hydraulic drum attachment for reducing brush, woody debris and fallen vegetation into smaller material. Fixed cutters work around a horizontal rotor; model selection depends on the excavator and its continuous hydraulic supply.
Bolt-on cutters remain fixed during cutting and can be replaced individually.
The drum cuts and grinds brush and woody material close to the ground.
Match the required continuous flow and pressure to the selected rotor configuration.

| Parameter | JY-TG-MC 70 | JY-TG-MC 120 | JY-TG-MC 200 |
|---|---|---|---|
| Compatible Excavator Class | 6–7 t (6.6–7.7 ton) | 10–15 t (11–16.5 ton) | 20–25 t (22–27.5 ton) |
| Number of Carbide Cutters | 11 | 16 | 24 |
| Continuous Operating Pressure | 245 bar (3550 psi) | 245 bar (3550 psi) | 245 bar (3550 psi) |
| Required Hydraulic Flow | 90 L/min (23.8 GPM) | 150 L/min (39.6 GPM) | 250 L/min (66.0 GPM) |
| Attachment Weight | 650 kg (1433 lb) | 1000 kg (2205 lb) | 1500 kg (3307 lb) |
Before ordering, send the machine identification and the connection, power and working information relevant to this product.
Check the model’s machine class and 650, 1000 or 1500 kg attachment weight at the working reach.
Provide pin diameters, pin centres, clear mounting width and coupler details.
Confirm 90, 150 or 250 L/min at the stated 245 bar operating pressure, with suitable cooling and return.
Confirm the motor’s case-drain connection and hose routing; check rotor clearance and guarding.
A drum carries fixed cutters around its horizontal rotor; a rotary brush cutter uses a blade assembly beneath a deck.
Yes. The documented bolt-on arrangement allows individual cutters to be removed and replaced.
No. Check continuous oil supply, attachment weight, interface and operating clearance together.
No universal diameter is given here. Material condition and the selected configuration affect the work.